Patient Cardiac Monitor (PM200-A)

High brightness 12.1" TFT LCD display (800×600)
Simultaneous 7-lead ECG waveform display
Analysis of real-time ST segment and arrhythmia
Protection against defibrillation and ESU interference
New SpO₂ technology for accurate low-perfusion readings
Stores up to 168 hours of graphic and tabular trend data
Drug dose calculation for up to 15 medications
Fanless design to reduce cross contamination
Networking capacity for up to 66 beds via HIS
Stores up to 750 groups of NIBP data for recall and display

ECG

  • Lead Mode: 5 Leads (R, L, F, N, C / RA, LA, LL, RL, V)

  • Lead Selection: I, II, III, aVR, aVL, aVF, V

  • Waveform: 3-channel, 7-lead simultaneous display

  • Gain: 2.5 / 5 / 10 / 20 mm/mV, auto

  • Heart Rate & Alarm Range:

    • Adult: 15–300 bpm

    • Neo/Ped: 15–350 bpm

  • Accuracy: ±1% or ±1 bpm (whichever greater)

  • Sensitivity: >200 µVp-p

  • Differential Input Impedance: >5 MΩ

  • CMRR: >105 dB (monitoring), >85 dB (diagnostic)

  • Electrode Offset: ±300 mV

  • Leakage Current: <10 µA

  • Baseline Recovery: <3 sec after defibrillation

  • Bandwidth:

    • Surgery: 1–15 Hz

    • Monitor: 0.5–35 Hz

    • Diagnostic: 0.05–100 Hz

  • ST Segment Monitoring: -2.0 to +2.0 mV

  • Calibration Signal: 1 mVp-p ±5%

  • Alarm and Review: Available

NIBP

  • Method: Oscillometric

  • Modes: Manual, Auto, STAT

  • Auto Measurement Intervals: 1–480 min

  • STAT Mode Duration: 5 min

  • Pulse Rate Range: 40–240 bpm

  • Alarm Type: SYS, DIA, MEAN

  • Measurement & Alarm Ranges:

    • Adult: SYS 40–270 / DIA 10–215 / MEAN 20–235 mmHg

    • Pediatric: SYS 40–200 / DIA 10–150 / MEAN 20–165 mmHg

    • Neonatal: SYS 40–135 / DIA 10–100 / MEAN 20–110 mmHg

  • Accuracy: ±5 mmHg mean error, ±8 mmHg std deviation

  • Overpressure Protection:

    • Adult: 297 ±3 mmHg

    • Pediatric: 240 ±3 mmHg

    • Neonatal: 147 ±3 mmHg

SpO₂

  • Range: 0–100%

  • Accuracy: ±2% (70–100%)

  • Resolution: 1%

  • Update Interval: 1 sec

  • Pulse Rate Range: 0–254 bpm ±2 bpm

  • Alarm Delay: 10 sec

  • Motion/Low Perfusion resistant

Respiration (RESP)

  • Method: Impedance (RA–LL)

  • Bandwidth: 0.3–2.5 Hz

  • Resp Rate Range:

    • Adult: 0–120 rpm

    • Neo/Ped: 0–150 rpm

  • Accuracy: ±2 rpm

  • Apnea Alarm: 10–40 sec

Temperature (TEMP)

  • Channel: 1

  • Range: 0–50 °C

  • Accuracy: ±0.1 °C

  • Resolution: 0.1 °C

  • Response Time: <10 sec

Physical

  • Display: 12.1″ high brightness TFT LCD (800×600)

  • Dimensions: 312 × 287 × 175 mm

  • Power Supply: AC 100–240 V, 50/60 Hz

  • Data Storage: 168 hr trends, 750 NIBP groups

  • Networking: Up to 66 beds via HIS

1 Patient monitor unit
1 ECG cable (5 lead)
1 set of ECG electrodes
1 SpO₂ probe
1 NIBP cuff
1 Temperature probe
1 Extension tube
1 Power wire
1 Grounding cable
1 User manual
1 Warranty
1 Certificate of qualification

Packed in 1 box
Box dimension: approximately 400 × 350 × 300 mm